1000W 2000W4000W 欧规220V 12V车载逆变器 Power Inverter

    Protective function
    (1)Low pressure alarm: buzzer with 1 Hz clearance 2 sound alarm.
    (2)Low pressure protection: buzzer with 1 Hz clearance 3 sound continuous alarn
    (3)Overpressure protection: buzzer with 1 Hz clearance 4 alarm.
    (4)Overheat protection :80土5, overheat protection buzzer 1 Hz gap 5 alarm.
现在咨询


Protective function
(1)Low pressure alarm: buzzer with 1 Hz clearance 2 sound alarm.

(2)Low pressure protection: buzzer with 1 Hz clearance 3 sound continuous alarn

(3)Overpressure protection: buzzer with 1 Hz clearance 4 alarm.

(4)Overheat protection :80土5, overheat protection buzzer 1 Hz gap 5 alarm.

(5)Overload protection: overload protection 10S automatic turn off output5S automatic recovery, three consecutive automatic lock.

(6)Short circuit protection: Output Short Circuit Protection 1s shutdown lock.

 
Installation requirements
Inverter installation with reference to local power requirements,

the installation site must be dry, clean and well ventilated.

Working temperature :-30°C to 40°C

Storage conditions :-10°C to 50°C

Relative humidity :0-95%, no condensation

Cooling: Forced ventilation

Product Specification:
 

Frequently asked questions and solutions
●Outside interference

●The inverter may be disturbed by some strong electromagnetic waves in use, such as nearby motors, power converters, strong magnetic fields, etc.

●The inverter has no reaction

1.The battery and inverter are not connected and reconnected.

2. The pole of the battery is reversed and the fuse is fused. Replace fuse.

●Low output voltage

1.Overload, load current exceeds nominal current, turn off partial load and restart.

2.The input voltage is too low. Ensure that the input voltage is within the nominal voltage range.

●Low Voltage Alarm

1.The battery is dead and needs to be charged.

2.Battery voltage is too low or poor contact, recharge, check battery terminals or clean terminals with dry cloth.

●Inverter without output

1.Battery voltage is too low, recharge or replace battery.

2.The load current is too high, turn off part of the load and restart the inverter.

3.Inverter overtemperature protection. Let the inverter cool down for a while and put it in a ventilated place.

4.The inverter failed to start and restarted.

5.Terminal connection, fuse, replace fuse.

●The inverter does not work

1.Check the power switch, fuse and battery connection or smoke.


Copyright © 2021 钦川科技有限公司 All rights reserved  技术支持:丽泽网络